Best Regards, Luciano Lingnau [Paessler Support] Add comment Created on Jun 20, 2016 10:41:37 AM by Luciano Lingnau [Paessler Support] Permalink Votes:0 Your Vote: Up Down Thanks Luciano, I have updated The next time you get error #223(no such instance) in PRTG, run the SNMP Tester but this time run the Custom OID test entering the following OID: 1.3.6.1.4.1.9.9.473.1.3.6.1.4.0.1.1. Learn more Top Tags 5804× prtg 1858× snmp 1476× sensor 948× wmi 628× notifications 478× maps View all Tags Trouble with SNMP traffic sensors Votes:0 Your Vote: Up Down This Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. click site

Once you have downloaded the latest version, you can install it directly over the version currently running. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy • Best Regards, Add comment Created on Jul 13, 2016 12:27:31 PM by Luciano Lingnau [Paessler Support] Last change on Jul 13, 2016 12:27:54 PM by Luciano Lingnau [Paessler Support] Permalink Votes:0 Add comment Created on Dec 17, 2013 1:22:21 PM by Patrick Hutter [Paessler Support] (7,144) ●3 ●3 Permalink Votes:0 Your Vote: Up Down Walk using SNMP Tester 5.1 ----------------------- New Test https://kb.paessler.com/en/topic/59631-no-such-instance-snmp-error-223

Nosuchinstance Snmp

Thanks, Mark Add comment Created on Jun 24, 2016 3:26:25 PM by mtknepper (0) ●1 Last change on Jun 27, 2016 5:31:22 AM by Luciano Lingnau [Paessler Support] Permalink Votes:0 Your best regards. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy •

Disable the other ones that work and you'll be good to go :) Add comment Created on Jul 26, 2016 6:37:31 AM by Stephan Linke [Paessler Support] Permalink Please log in So I suspected that the server was doing SNMPv1 but not SNMPv2c. You are invited to get involved by asking and answering questions! Snmp Error Codes Add comment Created on Dec 18, 2013 2:18:57 PM by Patrick Hutter [Paessler Support] (7,144) ●3 ●3 Permalink Votes:0 Your Vote: Up Down I got the following error "No such instance

The configuration and database will not be affected by installing the newer version over the old and the configuration is automatically backed up before this process. Prtg Snmp Error # -2003 What do you think? Use at your own risk. https://kb.paessler.com/en/topic/61528-no-such-instance-snmp-error-223 This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general.

With the PRTG tester, scanning the available interfaces, it seems to find them OK: Found standard interfaces: 1:06:00.0: (001) 06:00.0,Connected,1 GBit/s,Ethernet,06:00.0, 64 Bit 2:08:00.0: (002) 08:00.0,Connected,1 GBit/s,Ethernet,08:00.0, 64 Bit etc. Snmp No Such Object This means that the data contained in the SNMP Agent of the device was "re-ordered" and PRTG is no longer able to identify the data it was originally monitoring. Regards. Add comment Created on Apr 22, 2016 10:05:13 AM by Torsten Lindner [Paessler Support] Permalink Votes:0 Your Vote: Up Down Hey, thx for replying!

Prtg Snmp Error # -2003

If your device's indexes are changing during regular operation this could be a firmware/software issue in the SNMP Implementation, those indexes shouldn't change randomly. why not find out more I don't believe there are any ACLs between devices on the same subnet - and even if there were, is it possible for it to restrict what OIDs could be polled? Nosuchinstance Snmp Before applying any instructions please exercise proper system administrator housekeeping. Prtg Snmperr_no_vars Before applying any instructions please exercise proper system administrator housekeeping.

I have tried using auto discovery and manually adding the OIDs 1.3.6.1.2.1.2.2.1.8 and none of them work. get redirected here Does that work? Add comment Created on Apr 25, 2016 8:03:30 AM by Torsten Lindner [Paessler Support] Permalink Votes:0 Your Vote: Up Down Perfect! I am opening a ticket with Cisco to see what they think. Snmpget No Such Instance Currently Exists At This Oid

  • Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind.
  • Add comment Created on Dec 18, 2013 2:10:54 PM by Johannes Herrmann [Paessler Support] (1,320) ●2 ●2 Permalink Votes:0 Your Vote: Up Down With the period removed I get. ----------------------- New
  • Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind.
  • You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy •
  • Source: CISCO-CONTACT-CENTER-APPS-MIB Best Regards, Luciano Lingnau [Paessler Support] Add comment Created on Jun 21, 2016 9:29:57 AM by Luciano Lingnau [Paessler Support] Permalink Votes:0 Your Vote: Up Down Luciano, as suggested
  • The snmpd.conf on my Linux server is configured and if i use zabbix it can view the disk usage but zabbix no!

Instead of running a "Scan OIDLIB" test, could you please run a "Walk" using the base OID 1.3.6.1.2.1.2? Learn more Top Tags 5804× prtg 1858× snmp 1476× sensor 948× wmi 628× notifications 478× maps View all Tags No such instance (SNMP error 223) after reboot of Windows server You are invited to get involved by asking and answering questions! navigate to this website Find out how you can reduce cost, increase QoS and ease planning, as well.

This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general. Snmp Tester You are invited to get involved by asking and answering questions! System being rebooted causes SOME disk sensors to show: "The disk with serial number could not be found (code: PE156)" Add comment Created on Oct 6, 2016 8:31:55 AM by

This is very unusual.

Find out how you can reduce cost, increase QoS and ease planning, as well. Add comment Created on Sep 22, 2014 3:44:51 PM by kkunzler (0) ●1 Permalink Votes:0 Your Vote: Up Down Could you please forward us the results of both tests, including detailed Is this a problem? Alternatively you can download the software from our Paessler Service Center using your registered email and password.

Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. Add comment Created on Apr 25, 2016 8:03:30 AM by Torsten Lindner [Paessler Support] Permalink 6 Replies Votes:0 Your Vote: Up Down Hello, Thank you very much for your KB-Post. ESXi 5.1 Update 01 Build Number: 1065491 Best regards Kevin DORRELL Add comment Created on May 6, 2013 9:56:32 AM by dorreke (0) ●1 Permalink Votes:0 Your Vote: Up Down Hello, my review here The oid is for a cisco voice gateway to monitor active calls.

The PIM table is dependent upon both the instance table and the PG table; the instance index acts as the primary index and the PG index a secondary index. What results does that yield? Before this date they also were scanned without any issues. You are invited to get involved by asking and answering questions!

Add comment Created on Apr 23, 2012 10:56:03 AM by Patrick Hutter [Paessler Support] (7,144) ●3 ●3 Permalink Votes:0 Your Vote: Up Down Ah doh, didn't even notice the .1 - Free PRTG Download >> What is this? I have another 21 ESX hosts that seem to be behaving correctly, but the server team upgraded this one a couple of weeks ago, and since then I cannot read the Use at your own risk.

I appreciate your help and have been very impressed with your knowledge and ability to troubleshoot this issue. Free PRTG Download >> What is this? This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general. Deleting the sensor and recreating the sensor solves the problem.

Add comment Created on Dec 16, 2013 4:08:28 PM by NextNav (0) ●1 Last change on Sep 23, 2015 4:50:42 AM by Luciano Lingnau [Paessler Support] Permalink Votes:0 Your Vote: Up I can live withou the additional channels in the short term but would like to be able to monitor all channels on these services. Is there a way to tell PRTG to automatically update his lookup index as for device's network interfaces (Automatically update port name and number for SNMP Traffic sensors when the device This is what is retrieved by the SnmpB tool. 1: sysDescr.0 Raven XE EV-DO 2: sysObjectID.0 airlink.12.20 3: sysUpTimeInstance 7:18:54.22 4: sysContact.0 5: sysName.0 6: sysLocation.0 7: sysServices.0 76 8: ifNumber.0

Disclaimer: The information in the Paessler Knowledge Base comes without warranty of any kind. The message No such instance is the reply of the device when PRTG asks for the OID that it was monitoring until now and the device tells PRTG that "this 'address' How are you monitoring the sensor in PRTG? As you're not running the latest PRTG version I must kindly ask that you begin by updating to the latest stable release to confirm whenever the issue persists.

Login New Question Overview Unanswered Tags Users & Badges Back to www.paessler.com Intuitive to Use.Easy to manage. 150.000 administrators have chosen PRTG to monitor their network. But, when I try an SNMPv2c walk using MIBtools on my CA Spectrum, I can see all the version 2 interface MIB.

>